Description
This mod allows you to perform an air crossing of power lines by fixing the wires on high chimneys. The unusual solution for the through passage of power lines through dense industrial areas. Allows you to save on the construction of power lines bypassing, and even more so on laying the cable (upd: it turns out that the cable is unbalancedly cheap, therefore it does not allow). Finally, it's just a masterpiece of engineering!



! Application features !
1. You can use the Q/E keys to change the pitch.
2. Now all wires are connected automatically.


7 configuration options:
voltage, kV
chains
hanging height, m
length, m
110
1
50
200
110
2
50
200
110
1
75
300
110
2
75
300
110
1
100
400
110
2
100
400
20
2
40
160

- fires disabled
- there are pedestrian connections
- suitable for most vanilla factory chimneys
- does not cause short circuits in case of accidental contact with other structures

Technical note
Chimneys are rarely used as power line pylons. Usually, this design is used at thermal power plants, when the step-up electrical substation is significantly remoted from the engine room. In this case, the inputs are installed directly on the roof of the unit, from where the wires go to the traverses on the chimney. For example, in the USSR they were used at Vyborgskaya CHPP-17 (Leningrad), Arkhangelsk CHPP, Iriklinskaya State District Power Plant (Orenburg Region), Kashirskaya State District Power Plant, Konakovskaya State District Power Plant (Tver Region), Lukomlskaya State District Power Plant (Belarus). It can be assumed that one of the reasons for the low prevalence is the problem of interaction between enterprises: the installation of potentially dangerous structures on the territory of third-party enterprises does not seem such an easy task from a bureaucratic point of view.


Models, textures, code, debugging – Shotkey
[boosty.to]
7 Comments
Shotkey  [author] 3 Dec, 2024 @ 10:29am 
@CaseyJones
fixed
CaseyJones 2 Dec, 2024 @ 3:59pm 
The single platform air crossing, height 75m, length 300m, does not have collision turned off.
I noticed this a long time ago but forgot to mention it. Just realized it again on a new install.
Shotkey  [author] 26 Oct, 2022 @ 10:44am 
Tesmio, очевидно, что можно… я в описании об этом сказал.
Как будто у нас мастерская на 100% состоит из "полезных" модов )
Tesmio 26 Oct, 2022 @ 8:51am 
ну на самом деле сомнительная польза от этого здания
Если нужно проложить кабель по застроенной территории, просто можно проложить подземный
Zamboga 26 Oct, 2022 @ 3:55am 
Прикольно, не знал, что такие решения существуют, хотя я и специалист по тепловым электростанциям. Лайк.
Shotkey  [author] 26 Oct, 2022 @ 2:34am 
@ford-tim описанные случаи применения действуют на сегодняшний день.
Timpson34 25 Oct, 2022 @ 11:45am 
А нынче такое применяется?
Или является опасным местом и ликвидировано?