Stationeers

Stationeers

Not enough ratings
AdvancedAirLock
   
Award
Favorite
Favorited
Unfavorite
File Size
Posted
Updated
116.869 KB
1 Dec, 2018 @ 10:59am
6 Dec, 2018 @ 12:43pm
3 Change Notes ( view )

Subscribe to download
AdvancedAirLock

In 1 collection by Ren
Lucifers IC Codes
2 items
Description
This is an improved version of the Advanced Airlock display. a lot faster and all necessary settings are available, clearly recognizable and labeled.

The options include comparison variables for internal and external pressure.

If the pressure is very low, such as Mars, the external atmosphere be sucked in a small tank or with multiple passive vents to accelerate the pressure equalization.

the same materials are needed as with the display variant. No additional buttons or switches!
• 2 Doors / Airlocks Internal & External
• 2 ActiveVents Internal / External
• 1 gas sensor
The corresponding labels on the screws of the IC are available.
The external / internal change can be controlled from both doors via the door's own buttons.

UPDATE: Optionally, a switch can now be connected to lock the doors. Important: do not forget to turn the switch to open or it could be that you lock yourself out.

UPDATE: AVExt is now optional, the script can now be used as normal (single AV) or Adv Airlock (2 AVs)
5 Comments
KiltLife 14 Dec, 2018 @ 10:10am 
In my case, I'd be ok with the exchange. For instance, I have an enclosed battery room, with the same atmosphere mixture as the hallway entrance. The battery room generates quite a bit of heat that is captured there, and I transfer it to other areas via pipe/radiators, and logic controlled vents, circulating the air to provide heat and atmos to small separated building without its own heating/atmos generation. So the only thing that is transfered is a small amount of heat. I'm going to give it a go writing the code. I'll buzz you if I get stuck. Cheers.
Ren  [author] 13 Dec, 2018 @ 4:47am 
i understand, but it will mix a lil bit the air from both areas. the ic code for this will be very simple. if you need help with it than let me know that ;)
KiltLife 12 Dec, 2018 @ 9:24pm 
Good call...I hit the like button. What I was thinking wouldn't require vents for any pressure change, just open one door and close the other simultaneously.
Ren  [author] 6 Dec, 2018 @ 11:37am 
if you love it, be friendly and like it ;) to seperte areas is this script optimal too. can easy set up with integration of 2 Passive vents, for each Active Vent one, the active vents between the doors and the passives in the areas. eg warm area <-> passthrough <-> cold area
KiltLife 6 Dec, 2018 @ 9:45am 
Good stuff. Thanks for sharing. I'm just learing the IC chip coding and seeing stuff you all create is great for learning from.

This has got me thinking, that it would be cool to be able to have a set of doors that are Toggled (one opens - one closes) without the need for 3 consoles (2 slaved to the primary) for just a simple passthrough. I have an instance that doesn't need an airlock, but prefer to keep the areas seperate.