Stationeers

Stationeers

Not enough ratings
Automatic Advanced Furnace Electric Heater (Outdated)
   
Award
Favorite
Favorited
Unfavorite
File Size
Posted
153.166 KB
18 Jun, 2021 @ 9:36pm
1 Change Note ( view )

Subscribe to download
Automatic Advanced Furnace Electric Heater (Outdated)

In 1 collection by CowsAreEvil
Automatic Advanced Furnace
5 items
Description
This is the electric heater script for my automatic advanced furnace.
This will manage the temperatures and pressures for the storage tanks to be used by the furnace.
This is the electric version of the heater script.

Yes, it is slow. But is does not require gas.

World Save:
https://steamhost.cn/steamcommunity_com/sharedfiles/filedetails/?id=2520702039
Controller:
https://steamhost.cn/steamcommunity_com/sharedfiles/filedetails/?id=2520700872
Stack Writer:
https://steamhost.cn/steamcommunity_com/sharedfiles/filedetails/?id=2520701196
Extended Stack Writer:
https://steamhost.cn/steamcommunity_com/sharedfiles/filedetails/?id=2708613049
Gas Heater:
https://steamhost.cn/steamcommunity_com/sharedfiles/filedetails/?id=2520701390
Electric Heater:
https://steamhost.cn/steamcommunity_com/sharedfiles/filedetails/?id=2520701636
5 Comments
Mad Scientist Del 6 Apr, 2022 @ 8:14am 
so i have to say i'm having an odd issue getting the AC units to work like they do n the in your world save but having a problem with then feeding each other seems like the first 1 in the line just wants to overheat upwards to 10000C and doesnt feed n2 the other
CowsAreEvil  [author] 21 Jan, 2022 @ 11:08pm 
To simplify the calculations it is assumed that the gas mix in all the tanks is the same. When using the furnace the first time the gas nix can be different, especially if you prime the tanks with ice. This causes the temperature calculations to be wrong and the script will abort and retry. Smelt some simpler alloys first which will allow the tanks mix and recycle. Then come back to Stellite.
9Three 21 Jan, 2022 @ 4:45pm 
love the youtube series mate. europa is an amazing base. regarding this electric auto furnace, i cant seem to get the furnace pressurized enough for Stellite. it keeps dumping the furnace. not sure why.
Superbrain8 30 Nov, 2021 @ 3:15am 
fixed it, had to add a active vent to get enough pressure on the first AC unit.
Superbrain8 30 Nov, 2021 @ 1:17am 
hi, ive got troubles getting this running on Mars, have 2 passive vents connected to 2 of the AC units, tried with only 1 like in the World Save, but the hot side doesnt get hot, the pipes stay at 20°C (insulated pipes for everything, included insulated tanks)
Tried to prime the waste tank by smelting some ice and ignite it, but no dice.