[F&S] Room Temperature Control
Created by 123
Description Allows you to control the temperature in the room within the specified limits. This scheme works fine in small rooms and use hysteresis method to prevent unwanted rapid switching. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). 1 Gas Se...
[F&S] Solar Panel Tracking
Created by 123
Description Tracks the position of the sun, at night moves to the position of the sunrise.​ Optionally can turn on the light at nightfall, at the beginning of the morning, turns off the light. Works for Moon, Mars, Europa, Vulcano, and any modified suns an...
[F&S] Emergency Power System
Created by 123
Description Automaticaly turn on a generator(s)(Solid/Gas) when there is a low energy in batteries. Supports unlimited generators. Turns on generator(s) if charge less then 5%. Turns off generator(s) if charge more then 50%. Requirements 1 IC Housing. 1 In...
[F&S] Semi-Automatic Crafting Station
Created by 123
Description Sets the desired number of products and disables production when the specified value is reached​. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). 1 Any crafting station. 1 Stacker. 1 Chute corner. 1 (Optional) Led Display showing the de...
[F&S] Toggle Lights & Doors
Created by 123
Description Switches the lighting state when entering and exiting the room.​ Additionally can open doors with pxoximity sensor. Requirements 1 Occupancy Sensor (Kit Sensors) 1 IC Housing. 1 Integrated Circuit (IC10). Any type of (Kit Lights) instead of Wal...
[F&S] MaxMin Switch
Created by 123
Description Turns on the specified device at the maximum value and turns it off when the minimum value is reached. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). 1 Any device that needs to be turned on / off depending on the data 1 Any analyzer or...
[F&S] MinMax Switch
Created by 123
Description Turns on the specified device at the minimum value and turns it off when the maximum value is reached. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). 1 Any device that needs to be turned on / off depending on the data 1 Any analyzer or...
[F&S] Industrial Heat Pump
Created by 123
BROKEN Description Controls the temperature within the specified limits. Can be used to maintain the temperature in rooms, hydroponics, cool or heat gases and liquids to the desired level. Can transfer a large amount of heat energy, up to 1 MJ (1000 wall h...
[F&S] Full Auto Airlock
Created by 123
Description Fully automated airlock, just build and forget. Works in all kinds of modes, atmosphere to vacuum, atmosphere to atmosphere, vacuum to vacuum. Automatically equalizes pressure between transitions to different parts of the base (Unlike a in-game...
[F&S] Full Auto Airlock (Light Version)
Created by 123
Description Fully automated airlock, just build and forget. Retains the existing atmosphere in the pipe when the airlock closes, and release it when the same side is going to open again. Does not check the pressure behind the doors, if you need it, read th...
[F&S] Remote Buttons For Airlock
Created by 123
Description If you are using doors that do not have buttons (blastdoor, etc.), then you will need to remotely control the airlock. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). 1 Kit (Logic Switch) type Button. (Optional) 1 Kit (Logic Transmitter...
[F&S] Logic Reader\Writer\Batch
Created by 123
Description Does the same as the logic circuits reader/writer/batch, replaces 6 devices.​ Requirements 1 IC Housing. 1 Integrated Circuit (IC10). IC ports description Port Device D0 Logic Reader 1 (Optional) D1 Logic Reader 2 (Optional) D2 Logic Reader 3 (...
[F&S] Filtration Ratio Control
Created by 123
Description Set the filtering threshold and when the ratio is reached, the filtering is turned off.​ Automatically determines the filter type and sets the filtering to the desired value. Requirements 1 Integrated Circuit (IC10). 1 Kit (Atmospherics) type F...
[F&S] Timer Relay
Created by 123